left_title
Line Array
Power Amp
Mixing Console
Out Board
Microphone
Video
3D stereoscopic
Amx
Etc.
  회사소개 사업분야 제품소개 고객센터 견적의뢰 로고홈
> ǰҰ > qsc
 
𵨸 GX SERIES
QSC
÷ 1 QSC_GX Series .pdf
 
 
 
- Ǵ Ŀ ȭ ̷
- 4 8 Ű ýۿ ´ ȭ ִ ȿ
- Է´ : XLR, 1/4" TRS, Է Է ҽ ȣȯ
- ´ :  ޺, 1/4"(TS) ÷, Ȥ 2P, 4P ε Ʈ Ŀ ý .
- Ʈ ũ ġ ּȭ : 10.1ġ/257mm
- 淮-12.5kg
- ð Ī Ʈ
- µ ° Ϸ ջ ߴ Ŀ ڵ ȣϴ 巹(GuardRail)
- , ȣ, Ŭ Ȯ ִ LED г
- ۿ Ŀ ý ũν

GX Series

Channels

70V

8

4

RU

Net Weight/Shipping

GX3

2

300

425

2

11.5 kg/13.5 kg

GX5

2

500

700

2

12 kg/41 kg

 
SPECIFICATIONS GX3 GX5
8 ohms / 1 kHz (both channels driven) 300 W 500 W
8 ohms / 1 kHz (single channels driven) 350 W 600 W
4 ohms / 1 kHz (both channels driven) 425 W 700 W
4 ohms / 1 kHz (single channels driven) 500 W 850 W
Distortion (typical) 8 ohms: less than 0.05%
20 Hz - 20 kHz, 1 dB below rated power 4 ohms: less than 0.1%
Signal to Noise (20 Hz - 20 kHz) 100 dB
Input Sensitivity 1.2 Vrms
Voltage Gain (8 ohms) 32.2 dB 34.4 dB
Output Circuitry Class B 2-tier Class H
Power Requirements (1/8 power, pink noise at 4 ohms, 120V) 6.3A 6A
Frequency Response 20 Hz - 20 kHz, +0, -1 dB
Dynamic Headroom (4 ohms) 2 dB
Input Impedance (ohms) Greater than 20k (balanced)
Maximum Input Level +24 dB (16 Vrms)
Input Connectors (each channel) 3-pin XLR and 1/4" TRS, balanced, parallel
Phono, unbalanced
Output Connectors (each channel) Speakon?, 1/4", Binding Posts
Amplifier and Load Protection Short circuit, open circuit, thermal, RF protection
Load protected against DC faults
Front Panel Controls and Indicators Gain controls, 21 detents
Red Clip LEDs, proportional, 0.1% THD threshold
Green Signal LEDs, threshold -35 dB
Blue Power LED, AC on
Rear Panel Controls Full Range / Crossover switch
100 Hz, 3rd order LP (sub), 2nd order HP (top)
Dimensions Height: 3.5" (89 mm) 2RU
Width: 19" (483 mm)
Depth: 10.1" (257 mm)
Weight Net: 25 lbs (11.5 kg) Net: 26 lbs (12 kg)
Shipping: 30 lbs (13.5 kg) Shipping: 31 lbs (14 kg)
Agency Approvals UL, CE, RoHS/WEEE Compliant
AC Power Consumption

AC Current and Heating, 120 VAC

GX3 GX5
Operating Condition AC amps BTU / hr AC amps BTU / hr
Idle 0.2 44 0.3 60
8 + 8 ohms, 1/8 power 1 4.1 904 3.3 734
8 + 8 ohms, 1/3 power 2 6.1 1160 8.5 1456
8 + 8 ohms, full power 3 9.75 1109 16.2 1891
4 + 4 ohms, 1/8 power 1 6.3 1515 5.8 1160
4 + 4 ohms, 1/3 power 2 9.4 2105 11.2 2162
4 + 4 ohms, full power 3 15 2297 24.5 3754
1 1/8 power represents typical operating conditions
2 1/3 power represents peak program levels
3 Full power is breaker limited to short periods
For 230 V, multiply AC current by 0.5
For 100 V, multiply AC current by 1.25